简介概要

Density Dependence of Tunnel Fire Resistance for Aerogel-Cement Mortar Coatings

来源期刊:Journal Of Wuhan University Of Technology Materials Science Edition2020年第3期

论文作者:朱平华 JIA Zhi 王新杰 CHEN Chunhong LIU Hui XU Xiaoyan

文章页码:598 - 604

摘    要:Five kinds of mortars with density grades of 500,600,700,800,and 900 kg/m3 were prepared.Their thermal conductivity and compressive strength were measured,and the morphological changes before and after simulated tunnel fire were observed.To investigate the fire resistance,the interfacial temperature of a 30 mm thick aerogel-cement mortar and self-compacting concrete (SCC) in a simulated tunnel fire with the maximum temperature of 1 100 ℃ for 2.5 h was tested and recorded.The results showed that as the density decreased,both compressive strength and thermal conductivity of the aerogel-cement mortar exhibited an exponential decrease.The effective fire resistance time of the mortar with 500,600,700,800,and 900 kg/m3 for protecting SCC from tunnel fire were 97 min,114 min,144 min,> 150 min,136 min,respectively.700-800 kg/m3 was the optimum density for engineering application of tunnel concrete fireproof coating.

详情信息展示

Density Dependence of Tunnel Fire Resistance for Aerogel-Cement Mortar Coatings

朱平华,JIA Zhi,王新杰,CHEN Chunhong,LIU Hui,XU Xiaoyan

Department of Civil Engineering, Changzhou University

摘 要:Five kinds of mortars with density grades of 500,600,700,800,and 900 kg/m3 were prepared.Their thermal conductivity and compressive strength were measured,and the morphological changes before and after simulated tunnel fire were observed.To investigate the fire resistance,the interfacial temperature of a 30 mm thick aerogel-cement mortar and self-compacting concrete (SCC) in a simulated tunnel fire with the maximum temperature of 1 100 ℃ for 2.5 h was tested and recorded.The results showed that as the density decreased,both compressive strength and thermal conductivity of the aerogel-cement mortar exhibited an exponential decrease.The effective fire resistance time of the mortar with 500,600,700,800,and 900 kg/m3 for protecting SCC from tunnel fire were 97 min,114 min,144 min,> 150 min,136 min,respectively.700-800 kg/m3 was the optimum density for engineering application of tunnel concrete fireproof coating.

关键词: