废铜包铁针NH3-(NH4)2SO4-H2N(CH2)2NH2体系隔膜电解回收铜

来源期刊:中国有色金属学报2019年第8期

论文作者:杨建广 李树超 李陵晨 闫万鹏 丁龙 南天翔

文章页码:1721 - 1733

关键词:氨性体系;废杂铜处理;隔膜电解;电流效率;溶液循环

Key words:ammoniacal system; copper scraps treatment; membrane electrowinning; current efficiency; effluent recycle

摘    要:以电子加工行业产出的废铜包铁针为阳极,以不锈钢板为阴极,采用单因素试验法优化NH3-(NH4)2SO4-H2N(CH2)2NH2体系隔膜电解回收铜工艺。结果表明:在阴极液组成为NH3·H2O 4.5 mol/L、(NH4)2SO4 1 mol/L、Cu(Ⅱ) 30 g/L、乙二胺0.4 mol/L以及阴极电流密度为350 A/m2的条件下隔膜电解12 h后,在阴极可以得到表面光滑平整的阴极铜板,阴极铜纯度99.95%。由于部分阳极铜以+1价溶解于电解液中,使得实际隔膜电解回收废铜包铁针时阴极电流效率达到106%(以+2价铜电化当量计算),而阳极电流效率则为126%,脱铜后得到的铁针品位为99.3%。

Abstract: Using scrap copper coated iron needle as anode and stainless steel plate as cathode,the membrane electrolytic recovery of copper from scrap copper coated iron needle viaNH3-(NH4)2SO4-H2N(CH2)2NH2 system was optimized by single factor test. The experimental results show that, when the catholyte composition is NH3·H2O 4.5 mol/L,(NH4)2SO4 1mol/L, Cu (Ⅱ) 30 g/L, ethylenediamine 0.4 mol/L, and the cathode current density is 350 A/m2, a smooth cathode copper plate can be obtained at the cathode for 12 h electrowinning, and the grade of resultant cathode copper is 99.95%. The cathode current efficiency is 106% (calculated at +2 valence copper electrification equivalent), while the anode current efficiency is 126%, because some anode copper dissolves in the electrolyte at +1 valence. The grade of iron needle obtained after copper removal is 99.3%.

有色金属在线官网  |   会议  |   在线投稿  |   购买纸书  |   科技图书馆

中南大学出版社 技术支持 版权声明   电话:0731-88830515 88830516   传真:0731-88710482   Email:administrator@cnnmol.com

互联网出版许可证:(署)网出证(京)字第342号   京ICP备17050991号-6      京公网安备11010802042557号