模拟混凝土孔隙液中钢筋表面膜组成与腐蚀行为的关联

来源期刊:金属学报2011年第6期

论文作者:陈雯 杜荣归 胡融刚 时海燕 朱燕峰 林昌健

文章页码:735 - 742

关键词:钢筋; 模拟混凝土孔隙液; 极化曲线; Cl-

Key words:reinforcing steel; simulated concrete pore solution; polarization curve; Cl-

摘    要:采用XPS分析钢筋经模拟混凝土孔隙液浸泡后表面膜的化学组成,结合线性极化法和动电位扫描阳极极化曲线测试,研究钢筋在模拟混凝土孔隙液中表面膜化学组成与腐蚀电化学行为的关联.结果表明:钢筋在纯模拟液中处于钝化状态.在含Cl和不同pH值的模拟混凝土孔隙液中,随着Cl-浓度的增加和pH值的降低,钢筋的腐蚀电位负移,电流密度增大;钢筋表面钝化膜Fe2+的含量增加,Fe3+的含量减少.当模拟液中外加Cl-浓度达0.6mol/L或pH值降至11.31时,钢筋表面不发生钝化,但加入0.24mol/L NaNO2缓蚀剂后又可使钢筋钝化从而抑制腐蚀.

Abstract: It is well known that reinforcing steel in concrete can be protected from corrosion by forming a compact passive film on its surface in a concrete pore solution with high alkalinity.The corrosion behavior of the steel is related to its passivation and depassivation.The pH value and the Cl- concentration in a concrete pore solution are of the most important parameters affecting the passivity of reinforcing steel in concrete.In the present work, XPS analysis,linear polarization and potentiodynamic anodic polarization tests were used to study the relationship between the electro-chemical corrosion behavior of reinforcing steel immersed in a simulated concrete pore solution and the chemical composition of the steel surface film.The results showed that with the increase of the Cl- concentration or the decrease of the pH value in the solution,the corrosion potential of the steel shifted negatively and its corrosion current density rose,and the Fe2+ content of the steel surface film increased and the Fe3+ content decreased.The steel was in an active state in the solution with Cl- concentration higher than 0.6 mol/L or pH lower than 11.31,and the addition of 0.24 mol/L NaNO2 to the solution could protect steel from corrosion.

详情信息展示

模拟混凝土孔隙液中钢筋表面膜组成与腐蚀行为的关联

陈雯1,杜荣归1,胡融刚1,时海燕1,朱燕峰1,林昌健1

(1.福建省厦门市厦门大学化学化工学院化学系固体表面物理化学国家重点实验室)

摘 要:采用XPS分析钢筋经模拟混凝土孔隙液浸泡后表面膜的化学组成,结合线性极化法和动电位扫描阳极极化曲线测试,研究钢筋在模拟混凝土孔隙液中表面膜化学组成与腐蚀电化学行为的关联.结果表明:钢筋在纯模拟液中处于钝化状态.在含Cl和不同pH值的模拟混凝土孔隙液中,随着Cl-浓度的增加和pH值的降低,钢筋的腐蚀电位负移,电流密度增大;钢筋表面钝化膜Fe2+的含量增加,Fe3+的含量减少.当模拟液中外加Cl-浓度达0.6mol/L或pH值降至11.31时,钢筋表面不发生钝化,但加入0.24mol/L NaNO2缓蚀剂后又可使钢筋钝化从而抑制腐蚀.

关键词:钢筋; 模拟混凝土孔隙液; 极化曲线; Cl-

<上一页 1 下一页 >

相关论文

  • 暂无!

相关知识点

  • 暂无!

有色金属在线官网  |   会议  |   在线投稿  |   购买纸书  |   科技图书馆

中南大学出版社 技术支持 版权声明   电话:0731-88830515 88830516   传真:0731-88710482   Email:administrator@cnnmol.com

互联网出版许可证:(署)网出证(京)字第342号   京ICP备17050991号-6      京公网安备11010802042557号