简介概要

Effects of Chairside Polishing and Brushing on Surface Roughness of Acrylic Denture Base Resins

来源期刊:Journal Of Wuhan University Of Technology Materials Science Edition2009年第1期

论文作者:Seung-Kyun Kim Ju-Mi Park Min-Ho Lee Jae-Youn Jung

文章页码:100 - 105

摘    要:The effects of 3 chairside polishing kits and mechanical brushing on the surface roughness of 3 different acrylic denture base resins were compared. Acrylic denture base resins (auto-polymerizing, heat-polymerizing, injected heat-polymerizing resins) were examined after a tungsten carbide bur, and after chairside polishing using 3 polishing kits and pumice. The specimens were subjected to mechanical brushing using a wear tester to simulate 30 000 strokes of brushing. The surface roughness of the acrylic denture base resin specimens was measured using a contact pro-filometer. After the test, the random polished acrylic resins were evaluated by scanning electron mi-croscopy (SEM) and atomic force microscopy (AFM). Acrylic denture base resins polished using the 3 types of polishing kits had a smoother surface than those finished with the tungsten carbide bur (p<0.05). The surface of the resin polished by a TC cutter exceeded the Ra of 0.2 μm (p<0.05). The auto-polymerizing resin showed a significantly higher surface roughness than the heat-polymerizing resin and injected heat-polymerizing resin (p>0.05). In the case of polishing step wise, there was almost no change in surface roughness after brushing (p>0.05).

详情信息展示

Effects of Chairside Polishing and Brushing on Surface Roughness of Acrylic Denture Base Resins

Seung-Kyun Kim,Ju-Mi Park,Min-Ho Lee,Jae-Youn Jung

摘 要:The effects of 3 chairside polishing kits and mechanical brushing on the surface roughness of 3 different acrylic denture base resins were compared. Acrylic denture base resins (auto-polymerizing, heat-polymerizing, injected heat-polymerizing resins) were examined after a tungsten carbide bur, and after chairside polishing using 3 polishing kits and pumice. The specimens were subjected to mechanical brushing using a wear tester to simulate 30 000 strokes of brushing. The surface roughness of the acrylic denture base resin specimens was measured using a contact pro-filometer. After the test, the random polished acrylic resins were evaluated by scanning electron mi-croscopy (SEM) and atomic force microscopy (AFM). Acrylic denture base resins polished using the 3 types of polishing kits had a smoother surface than those finished with the tungsten carbide bur (p<0.05). The surface of the resin polished by a TC cutter exceeded the Ra of 0.2 μm (p<0.05). The auto-polymerizing resin showed a significantly higher surface roughness than the heat-polymerizing resin and injected heat-polymerizing resin (p>0.05). In the case of polishing step wise, there was almost no change in surface roughness after brushing (p>0.05).

关键词:

<上一页 1 下一页 >

相关论文

  • 暂无!

相关知识点

  • 暂无!

有色金属在线官网  |   会议  |   在线投稿  |   购买纸书  |   科技图书馆

中南大学出版社 技术支持 版权声明   电话:0731-88830515 88830516   传真:0731-88710482   Email:administrator@cnnmol.com

互联网出版许可证:(署)网出证(京)字第342号   京ICP备17050991号-6      京公网安备11010802042557号