Effects of electric parameters on corrosion resistance of anodic coatings formed on magnesium alloys
来源期刊:中国有色金属学报(英文版)2010年增刊第2期
论文作者:张淑芳 胡光辉 张荣发 贾志翔 王丽君 王义君 胡长员 何向明
文章页码:660 - 664
Key words:magnesium alloys; micro-arc oxidation; electric parameters; corrosion resistance
Abstract: Anodic coatings were obtained by micro-arc oxidation on AZ91HP magnesium alloys in a solution containing 10 g/L NaOH and 8 g/L phytic acid. The effects of electric parameters including frequency, final voltage, duty cycle and current density on the corrosion resistance of anodic coatings formed on the magnesium alloys were investigated by using an orthogonal experiment of four factors with three levels. The results show that the final voltage plays a main role on the coating properties. The orders of affecting corrosion resistance and coating thickness are separately ranked from high to low as, final voltage>duty cycle>current density>frequency and final voltage>current density>frequency>duty cycle. The final voltage influences the corrosion resistance of the anodized samples mainly by changing the surface morphology and coating thickness.